loading page

High-power, short-duration ablation of the atrioventricular node
  • +4
  • Mahmoud Alsaiqli,
  • Rafsan Ahmed,
  • Leonell Freytes,
  • Ola Rehaw,
  • Harshith Chandrakumar,
  • Adam Budzikowski,
  • Ahmed Jallad
Mahmoud Alsaiqli
Department of Medicine SUNY Downstate Medical Center Brooklyn NY 11226

Corresponding Author:[email protected]

Author Profile
Rafsan Ahmed
Department of Medicine SUNY Downstate Medical Center Brooklyn NY 11226
Author Profile
Leonell Freytes
Department of Cardiology SUNY Downstate Medical Center Brooklyn NY 11226
Author Profile
Ola Rehaw
Internal Medicine Department University of Alabama at Birmingham Birmingham Alabama 35233
Author Profile
Harshith Chandrakumar
Department of Medicine SUNY Downstate Medical Center Brooklyn NY 11226
Author Profile
Adam Budzikowski
Department of Cardiology SUNY Downstate Medical Center Brooklyn NY 11226
Author Profile
Ahmed Jallad
Department of Cardiology SUNY Downstate Medical Center Brooklyn NY 11226
Author Profile

Abstract

Introduction Atrioventricular node (AVN) radiofrequency ablation is a highly effective treatment of atrial tachycardias resistant to other management modalities. There are limited studies that compare different radiofrequency ablation catheters. Our study aimed to compare the effectiveness of several types of ablation catheters in AVN ablation. Methods We identified patients who underwent AVN ablation for different indications at our institution. Data related to patients and procedures were collected through retrospective chart review. The radiofrequency catheters used were: plain non irrigated, externally irrigated (EI), and contact force sensing with 10-20 gm of force in two different settings: low power long duration (LPLD) (30W, 45°C, and 60 sec) and high-power short duration (HPSD) (50W, 43°C, and 12 sec). We compared the different catheters in terms of success rate using logistic regression and lesion time using linear regression. Results We identified 66 patients who underwent AVN ablation, out of which 31 were female (47%). The patients were elderly, with a mean age of 73.27 years. The indications were resistant atrial fibrillation in 74%, atrial flutter in 18%, and other atrial tachycardias in 8% of patients. Types of catheters used were plain non irrigated in 48%, EI in 2%, LPLD in 16%, and HPSD in 34% of patients. All ablation procedures were successful with no immediate post-procedure complications. Regarding lesion time, HPSD was significantly shorter compared to plain catheters by 403.42s[-631.67, -175.17]. Conclusions Radiofrequency ablation of AVN is a highly effective treatment modality for atrial tachyarrhythmias that failed other management methods. While plain catheter, LPLD, and HPSD were equally safe and effective, HPSD catheter had significantly shorter lesion time and thus procedure time.