Please note: We are currently experiencing some performance issues across the site, and some pages may be slow to load. We are working on restoring normal service soon. Importing new articles from Word documents is also currently unavailable. We apologize for any inconvenience.

loading page

The High-pO2 Method to Prevent U-Loss During Single-Aliquot Hematite (U-Th)/He Measurement: Development, Implementation, and Automation
  • Florian Hofmann
Florian Hofmann
University of Southern California

Corresponding Author:[email protected]

Author Profile

Abstract

Single-aliquot (U-Th)/He dating of iron-oxides requires less mass and has a higher spatial resolution than the two-aliquot approach, and is, therefore, a more reliable tool for quantifying the timescales of weathering processes, fault activity, and the development of soils and surfaces. Highly helium-retentive hematite samples must be heated to 1000-1100 °C to completely degas He, but we show that U is lost progressively during laser-heating starting at ~900 °C, with major U-loss at ~980 °C and complete U-loss at 1050-1100 °C. This partial or complete loss of U leads to incorrect (U-Th)/He ages that appear older than the true ages. We performed a series of heating tests on hematite and goethite aliquots with independently determined (U-Th)/He ages of 10-1761 Ma in which the helium release was determined by isotope-dilution mass spectrometry and phase change was monitored by infrared spectroscopy. As hematite is heated, reduction of Fe3+ causes a phase change to magnetite and then to elemental Fe. We correlate the onset of U-loss to the phase change from hematite to magnetite. By raising the temperature of this phase transition using a high oxygen partial pressure (pO2) in the sample chamber during laser-heating, we show that the onset temperature of U-loss is equally raised. Samples can therefore be safely degassed at higher temperatures without any detectable U-loss. In our implementation of this technique, the O2 in the sample chamber is being withdrawn from a tank using a pipette and it is being released before and captured after the degassing process on activated charcoal in a cold finger with a movable LN2 Dewar flask. We describe the automation of this process for routine degassing of hematite samples. We show that an average age calculated on a reference hematite sample from replicate aliquots (n=12), which were analyzed using this procedure, has a relative uncertainty of 2% (1σ), and is within uncertainty of the previously measured two-aliquot age. We suggest this high-pO2 degassing procedure as a way to precisely and reproducibly determine single-aliquot hematite and goethite (U-Th)/He ages.